Fs-450m specifications, Resolution and display range – J.P. Instruments Fuel Scan 450M Pilots Guide User Manual
Page 26
![background image](/manuals/546509/26/background.png)
Page 24
FS-450M Fuel Scan
FS-450M Specifications
FAA Approved
Fuel Flow Transducer:
STC SA00432SE
Display Size:
2
1/4
in panel mount
2.6 in. sq., 2.5 in. deep incl. conn.
Operating Temperature
Range:
-40 to 195 oF
STEP
AUTO
FlowScan® 450M
Left
Right
Fuel flow function
Flow
per hr
JPI
Always shows fuel flow
of each engine
shows all other fuel
parameters
AUTO enters the automatic
scan mode
STEP enters manual scan
mode, steps through each
paramerter
Resolution and Display Range
display
maximum display value
resolution
K factor range: 5,000 to 99,990
10
Fuel flow: Accuracy (8 to 60 GPH)
1 %
140.0 GPH at K factor 85,000
0.1 GPH
410.0 GPH at K factor 29,000
0.1 GPH
820 PPH at K factor 85,000
1 PPH
2400 PPH at K factor 29,000
1 PPH
560 LPH at K factor 85,000
1 LPH
1640 LPH at K factor 29,000
1 LPH
Fuel Remaining: 999.9 gal
0.1 gallons
999 pounds., liters
1 pound., liter
Fuel Used: 999.9 gal.
0.1 gallons
9999 pounds., liters
1 pound., liter
Time to Empty: 50 hours
1 minute