Troubleshooting – Hornady Lock-N-Load Auto Charge User Manual
Page 7

7
TROUBLESHOOTING
The Hornady Lock-N-Load
®
Auto Charge
™
is a highly sensitive instrument, which
must be repaired and serviced by a factory qualified technician to maintain the
warranty.
ADJUSTING TRICKLE SPEED
To adjust trickle speed:
1) Turn unit on and let it stabilize.
2) Press and hold
CAL button for 6 seconds. The screen should display “SET.”
3) Press the
SPEED button to increase the trickle speed.
4) Normal factory setting is between 0.5 and 0.8.
5) Press the
UNITS button to decrease the trickle speed.
6) After reaching the new trickle speed, press and hold
BACK/CANCEL to store
trickle speed and return to normal operation.
NOTE: Do not decrease the inner value lower than 0.0, or increase it more than 25.5.
NOTE: The new trickle speed should be permanently stored even if the Auto Charge is turned off.
ADJUSTING TRICKLE START TIME
Scale must be zeroed out with no target displayed. Additionally, if the scale is shut
off or BACK/CANCEL is used, this number will need to be reset.
To increase the trickle time by adjusting the point when the unit goes from quick
dispense to trickle:
1) Turn unit on and let it stabilize.
2) Hold
MODE button for 2 seconds.
3) The screen will display “0.2” to indicate the trickle will begin trickling
approximately 0.2 grains before the target weight.
4) Repeat Step 2 until desired start time is reached.
CHANGE MOTOR DISPENSE MODE
To change the motor dispense mode from Normal to Power:
1) Turn unit on and let it stabilize.
2) Hold
DISPENSE button for 2 seconds to switch from Power mode and Normal
mode.
n
Power mode will cause the trickle speed to twitch harder. This will shorten
trickle time but may cause more overthrows.
n
Normal mode is the default setting.