E. CALIBRATION
For optimal performance, turn unit on and
allow 5-15 minutes to warm up.
Verify powder pan has been removed, and
that the red scale plate is empty.
Press
CAL button once and unit will
display “
0.00g
“.
Press
CAL button and the unit will then
calibrate while displaying “
----“.
When “
10.00g
“ is displayed, place the
10g weight on the center of the scale plate
and press
CAL. The unit will then continue
calibrating while displaying “
----
“.
When “
50.00g
“ is displayed, remove the
10g weight, and then place the 50g weight on the center of the scale plate. Do
not let the weight touch the powder dispense tube.
Press
CAL. The unit will then finish calibrating while displaying “----“.
After calibrating, the unit will briefly display “
PASS” before returning to normal
operation, and display the “
50.00g
“ weight in grains.