beautypg.com

L.B. White I-40 Infraconic Spark Ignition User Manual

Page 21

background image

20

Problem 2

Heater lights

but will not

stay lit

Is heat

er’s

dust f

ilt

er

reasonably

clean

?

R

emo

v

e

ignit

er and

clean its electr

ode.

R

emo

v

e

and clean

the f

ilt

er

.

Ye

s

No

Ye

s

Is high

v

oltage ignition

lead in good

condition?

Is ignit

er clean?

Inner combustion

cone or main

burner orif

ice are

plugged with dir

t.

Clean these

com

ponents.

No

Is

heat

er pr

operly

gr

ounded and are all

heat

er gr

ounds in good

condition?

Check all gr

ounds leads f

or:

- Corr

oded t

erminal

- Continuity/R

esistance

- Loose connections

R

epair or replace as

necessar

y.

Ye

s

No

Is pr

oper

pressure supplied

to

the heat

er?

Supply pr

oper pressure

and check f

or block

ages

in gas hose. R

e

fill

L.P

. gas container

s.

Ye

s

No

No

V

erify resistance v

alue of

lead. Should be

1 ohm or less. V

erify lead

has good connections, and

no cuts.

R

eplace if necessar

y.

Ye

s

Heater

backflashes

gas through

air inlet.

Problem 3

Is inner

cone seam

fractured or is tip

damaged or

missing?

R

eplace combustion cone.

Ye

s

No

Are

air housing

burner orif

ice,f

ilt

er

,

v

enturi tube, or inner cone

plugged with

dir

t?

Clean these

Com

ponents.

No

Is pr

oper

gas pressure

supplied t

o

heat

er?

Check f

or pr

oper

gas pressure.

Pr

oper pressure at

high heat should

read 5 PSIG.

Ye

s

No

Combustion Cone Kits

Par

t

N

umber

57

0

1

3

0

Ye

s

Are burner

assembly

nuts loose?

Ye

s

Tight

en the nuts

Is the burner

plat

e or burner

gask

et

crack

ed?

Ye

s

R

eplace the burner

plat

e or gask

et

No

No

Is Inner cone w

eld

seam aligned t

o

burner plat

e

no

tch?

No

P

osition the inner cone

w

eld seam in burner

plat

e no

tch.