L.B. White I-34 Infraconic Pilot Ignition User Manual
Page 13
FIG. 10
4.
Repeat steps 2 and 3 until water runs clean.
5.
Remove the plastic bag and inspect the cones and
venturi tube to make sure these areas are clean.
6.
Shake the heater vigorously to clear water off of the
pilot orifice and combustion cones to allow proper
ignition of gas at the combustion cones.
7.
Return the heater to its original hanging position.
8.
Relight the heater to dry out the cones and the
venturi tube.
B. INSTACLEAR™ PILOT CLEAN-OUT
--
For heaters so equipped, the InstaClear™ clean-out
provides a fast, easy method of cleaning the pilot
orifice without removal of the orifice.
--
The clean-out is virtually maintenance free. However,
if the pilot orifice of the clean-out should ever need
replacement, refer to the orifice service instructions in
this manual.
A. To operate the clean-out:
-- Fully depress push button at top of clean-out.
See Fig. 11.
-- Ensure button is flush with top of body to allow
proper cleaning of orifice hole.
-- When accomplished, a small pin will move
through the orifice hole to clean any material
from the hole.
B. Use the clean-out feature at the start of each new
growing cycle, or when plugging of the orifice occurs.
Indications of pilot orifice plugging are:
-- Weak pilot flame center
-- Pilot outages
FIG. 11
C. DUST FILTER
A. During continued heater use:
- Remove filter and shake off dust.
- Do not squeeze or tap filter while filter is installed
on heater. Doing so will cause dust to be blown
into venturi tube or combustion cones.
B. A f te r c o n t i n u e d h e a te r u s e o r b e fo r e b u i l d i n g
repopulation:
- Remove filter and shake off dust.
- Use compressed air or water ( standard faucet
pressure) to clean it.
- Do not use high pressure water, air, or a washing
machine. Filter material damage may occur.
- If water is used, squeeze out excess water from
filter before installation.
- Let filter dry before lighting heater.
WATER HOSE
13
PLUNGER
BUTTON
TOP OF BODY
TOP OF BODY
PUSH
BUTTON