Assemble the strips and insert into last tube. Edge of strip
is flush with end of tube. See Fig. 9. Refer to Fig.10 for
installation of vent hood.
FIG. 9
FIG. 10
MANUAL SHUT-OFF VALVE, HOSE
& REGULATOR ASSEMBLY
REGULATOR
NIPPLE
VALVE, MANUAL
SHUT-OFF
GAS HOSE
ADAPTER
SEDIMENT TRAP
TO CONTROL
VALVE INLET
REGULATOR VENT
GAS FLO
W
1.
Assemble the components together. See Fig. 12.
T h i s v i ew s h ow s g e n e r a l a s s e m b l y o f t h e
components. The regulator must always be mounted
so its vent, regardless of location on the regulator, is
always pointed downward. Ensure hose is positioned
away from the heater.
2.
Tighten all connections securely and check for gas
leaks.
FIG. 12
SECOND STAGE
REGULATOR
13
Assemble the tee, nipple, and cap to the nipple at the gas
inlet of heater. See Fig. 11. Tighten securely. The sediment
trap assembly must always be mounted in a ver tical
position. Check all connections for gas leaks using
approved gas leak detectors.
FIG. 11
TUBE
VENT HOOD
PUSH FIRMLY ONTO END TUBE
AIR TURBULATION STRIPS & VENT HOOD
SEDIMENT TRAP ASSEMBLY
PUSH VENT HOOD FIRMLY ONTO END OF
LAST TUBE, OUTLET DOWN. FLAPPER OF
VENT HOOD MUST CLOSE COMPLETELY.
PLE
HOSE ADAPTER
TEE
NIPPLE
CAP
NIPPLE
FROM HEATER