Initial setup, Fig. 5 fig. 6 – L.B. White Sentinel Radiant Tube AT150 Center Mount User Manual
Page 10
JOIST
OPEN EYE HOOKS
IN LINE WITH
EYE BOLTS ON
BURNER BOX
OPEN EYE BOLT
AIR INLET
1 FT
BURNER
DISCHARGE
TIGHTEN HOOKS
SECURELY
10
1. Plan the installation. Determine location for the
heater to optimize its heat pattern, keeping in mind
cooler regions in the house (end walls, and curtains)
and clearances to combustibles.
2. Hang the burner box. See Fig. 5. Maintain clearances
to combustibles as shown in Fig. 1.
3. From the burner box chain, measure the distances
shown in Fig. 6. Aligning to the center of the burner
box discharge, hang chains at these points, using
open eye hooks.
FIG. 5
FIG. 6
INITIAL SETUP
A
B
C
D
E
F
G
HEATER
LENGTH
TRUSS
CENTERS
A - B B - C C - D D - E E - F F - G
4 FOOT
30 FOOT
40 FOOT
50 FOOT
4
4
4
4
4
4
12
12
12
8
8
8
12
12
8
5 FOOT
30 FOOT
40 FOOT
50 FOOT
5
5
5
5
5
5
10
10
10
10
10
10
5
10
5
10 FOOT
30 FOOT
40 FOOT
50 FOOT
5
5
5
5
5
5
10
10
10
10
10
10
5
10
5
*
*
*
*
*
* A SUPPORT MUST BE CREATED BETWEEN THE TRUSSES
BURNER BOX
HANGING CHAINS
HANGING CHAIN DISTANCES
(FT)
(FT)
(FT)
(FT)
(FT)
(FT)