Gas selector valve – L.B. White 170 Dual Fuel User Manual
Page 14
14
14
1.
This feature allows the heater to operate on either
propane or natural gas without changing out the
burner orifice. The gas selector valve is located
between the gas control valve and the burner. Gas
selection is made by sliding the locking sleeve up and
repositioning the valve’s handle. THIS IS NOT A
MANUAL GAS SHUT OFF VALVE.
2.
Refer to Figs. 14 and 15. The valve handle must be
properly positioned for the specific gas being used.
FIG. 14
FIG. 15
3.
The handle must be fully set at 90 degrees to gas
flow (propane gas) or parallel to gas flow (natural gas)
for proper operation. Do not operate the heater with
t h e va l ve h a n d l e s e t b e t we e n e i t h e r p o s t i o n ,
otherwise improper operation will occur.
4.
The valve’s handle can be locked to prevent improper
positioning. Use the hole provided. See Fig. 16.
FIG. 16
Gas Selector Valve
HANDLE POSITION
PROPANE GAS
HANDLE POSITION
NATURAL GAS
LOCKING SLEEVE
(SLIDE UP TO REPOSITION
VALVE HANDLE)
- AW060 (18 pages)
- AW325 (18 pages)
- AW250 (18 pages)
- AD250(Spark Ignition) (30 pages)
- AB250 (18 pages)
- AW250(building controller) (31 pages)
- AD250 (31 pages)
- AW250(Smart Box controller) (31 pages)
- FA-MCS-D (21 pages)
- FA-MCS (22 pages)
- COMBO-MCS (23 pages)
- AD060 (30 pages)
- 60 Classic (16 pages)
- 115 Classic (16 pages)
- 170 Classic (16 pages)
- Pilot (94 pages)
- I-17 Infraconic Spark Ignition (28 pages)
- I-17 Infraconic Spark Ignition (26 pages)
- I-3 Infraconic (26 pages)
- I-5 Infraconic (24 pages)
- I-17 Infraconic (28 pages)
- Guardian with Smart Sense - Hot Surface (60K / 100K) (31 pages)
- Guardian with Smart Sense - Spark Ignition (60K / 100K) (31 pages)
- Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) (30 pages)
- 100 Tradesman Portable Forced Air (24 pages)
- 170 Tradesman Portable Forced Air (28 pages)
- 400 Tradesman Portable Forced Air (30 pages)
- Portable Gas Heaters (99 pages)
- 45-75K Tradesman (30 pages)
- HW 120 Therma Grow (28 pages)
- HW120 Plus Therma Grow (30 pages)
- 220 Therma Grow (30 pages)
- 220 Plus Therma Grow (32 pages)
- 300 Director (27 pages)
- 350 Premier Dual Fuel (33 pages)
- 80 Premier (34 pages)
- 350 Premier (33 pages)
- 100 Workman - Standard LP (18 pages)
- 100 Workman - NG Low Pressure (18 pages)
- 250 Norseman (18 pages)
- 200 Norseman (18 pages)
- 225 Workman (18 pages)
- 322 Norseman - Horizontal (18 pages)
- Sentinel Radiant Tube AT150 40' Center Mount (32 pages)