beautypg.com

5 event information, Event information – AKiTiO Taurus Super-S LCM User Manual

Page 16

background image

Taurus Super-S LCM LCD Display

[14]

3.5 Event Information

In addition to the details about the hardware and device configuration, the LCD display will also

show certain event information. Following is a list of possible messages and their meanings.

[HDD Error / Remaining 1xHDD]

When using RAID 0 and one of the drives fails, the alarm will go off and the display indicates

that only one good drive remains. Refer to the HDD LED’s in order to locate the defective drive.

[RAID Warning / Degraded Array]

When using RAID 1 and one of the drives fails, the alarm will go off and the display shows this

message. Press the [OK] button to temporarily mute the alarm and use the HDD LED’s in order

to locate the defective drive.

[XX Cable / Connected]

Shows which cable has been connected.

[Cable / Disconnected]

Shows when the cable has been unplugged.

[Rebuilding… / Hrs left xhxxmin]

Shows during the rebuild process of a RAID 1 array with an approximate time in hours and

minutes indicating how long it takes until the backup is done.

[Alarm / High Temperature]

Indicates critical temperature (>60˚C).

[Alarm / Fan Failure]

Indicates a fan failure or unexpectedly slow RPM.

[Detecting Disk / Starting…]

Shows during start up of the system.

[XX / Starting …]

Shows during start up of the system.

[Check DIP Switch]

Shows when trying to change the RAID mode via LCD display but the DIP switch is set to a

specific RAID mode already.

[Modify DIP Switch]

Shows when pressing Abort after changing the DIP switch to a different RAID mode.

Remember to modify the DIP switch and set it back to the previous mode if you don’t want to

change it.

[RAID Mode Locked]

Shows when trying to change the RAID mode via LCD display but the DIP switch is set to lock

the settings.