6 testing & final assembly, Filling the differential – ARB RD136 User Manual
Page 38

6 Testing & Final Assembly
36
Turn the compressor (or alternate air source) on to charge the air
supply up to its maximum pressure.
 Rotate one wheel by hand. 
 The wheel should rotate freely and the opposite wheel should be 
turning in the opposite direction without any resistance or 
mechanical noise from within the differential. 
Turn the Air Locker switch to the ‘ON’ position. The illuminated
symbol on the switch cover should light up.
 Rotate the same wheel again. 
 Both wheels should rotate together. 
 Turn the switch off again. 
 Rotate the same wheel. 
 The wheels should again rotate in opposite directions. 
6.3
Filling the Differential
NOTE : Consult the ARB Air Locker Operating & Service
Manual for recommendations on differential lubricant 
specifications. 
 Refill the differential until level with the filler hole. 
 Rotate the differential center 2 full turns. 
 Check the oil level and add oil if necessary. 
 Apply thread sealant to filler plug before inserting. 
 Replace the filler plug. 
 Clean the differential housing of any oil or grease that may collect 
dirt or other abrasive particles.