beautypg.com

Warning, Troubleshooting – Bissell 7901 User Manual

Page 20

background image

20

WARNING:

To reduce the risk of
fire, electric shock or
injury unplug from outlet
before servicing.

Troubleshooting

SmartTemp Ready Light does not illuminate.

Possible Causes

Remedies

The SmartTemp switch is not

Turn on the SmartTemp switch.

turned ON.

The machine Power Switch is not

Both switches must be ON to

turned ON.

activate the SmartTemp Ready Light.

Reduced spray or no spray

Possible Causes

Remedies

Bladder may be empty.

Refill bladder with hot tap water.

SmartMix bottle may be empty.

Fill with BISSELL Advanced Cleaning
Formula for cleaning or water if
rinsing,or using the Scotchgard
protector applicator.

The filter may be clogged.

Clean out Flow Indicator Filter, page 17.

Tanks may not be seated properly.

Turn power OFF; remove & reseat
tanks. Inspect for presence of seals.

Pump may have lost prime.

Turn power OFF; after 1 minute turn
ON and depress trigger.

The Pump Belt may be broken.

Turn the machine OFF and unplug
from the outlet. To check if a Pump
Belt has broken, you will need a flat
head screwdriver. Insert the blade end
into the lower slot of the Belt Access
door to release the lower snap. If
necessary, insert the blade end into
the upper slot to release the upper
snap. Examine the belt for breakage.
You should be able to see the Pump
Belt looped around the motor shaft. If
it is broken or missing, please refer to
Replacement Parts on pg.23 before
calling Consumer Services. Complete
installation instructions will
accompany the replacement belt.

Insert
Screwdriver
Blade Here

Lift Here