OPERATION (continued)
7
WATER HEATER
Water temperature is sensed by an electronic water 
temperature probe inserted into the water tank. 
This temperature signal is fed to the controller. 
 
The setpoint temperature is adjustable. The 
controller sends a command signal to the power 
board based upon a comparison between the 
setpoint temperature and actual temperature. 
See page 15. 
 
The power board energizes the heating elements 
based on the command signal from the controller. 
 
Excessive temperature will trip the hi-limit safety 
switch. The hi-limit will automatically reset when 
the brewer cools. 
WATER FLOW
 
POUR-OVER FEATURE 
 
Pouring any amount of water into the pour-over 
opening and into the basin pan forces an identical 
amount of heated water out of the tank and through 
the spray head. 
 
AUTOMATIC OPERATION 
 
Pressing the BREW key energizes the solenoid 
valve, allowing water from an external water supply 
to flow into the water tank. The incoming water 
forces heated water out of the tank to perform the 
brew. 
 
The solenoid uses a flow control device so that 
flow is consistent between 20 p.s.i. and 90 p.s.i. 
 
The length of time the solenoid is open is controlled 
by the time setting of the controller. See page 18. 
 
After the solenoid closes, water will continue to flow 
to the brew chamber until 
the water level in the tank falls below the brew 
pickup, breaking the siphon. 
 
HOT WATER FAUCET 
 
The faucet water coil is submerged in the hot water 
tank and draws heat from the brew water. Water 
going to the water coil is not controlled by the 
solenoid valve. 
 
Hot water is provided at the faucet, at supply water 
pressure, any time the faucet shut-off valve is 
OPEN
.
Fig. 6 Water Flow Diagram
Fig. 5 Heat Control Diagram