Product overflows container
Weak product
1. Dispense switch
2. Dispense solenoid valve
1. Water temperature
2. Whipper motor
3. Frother
4. Dispense solenoid valve
5. Auger drive
6. Auger spring
7. Auger motor
8. Rinse/Run switch
Refer to
Service -
Dispense Switch
for testing procedures. See page 16
Remove the solenoid valve and clear
any obstructions. Rebuild or replace
the valve if necessary. See page 26
Place an empty container beneath
the dispense tip. Initiate a dispense
cycle and check the water tempera-
ture immediately below the dispense
tip with a thermometer.
(A) Reading for mechanical thermo-
stat models should be 180
°
F to 200
°
F
(see thermostat temperature settings
decal in
USER NOTICES
on page 3.)
Refer to
Service
- Whipper Motor for
testing procedure. See page 18
Refer to
Service
- Frother Compo-
nents. See page 18
Refer to
Service
- Dispense Solenoid
Valve for test procedures. See page
26
Refer to
Service
- Auger Drive Com-
ponents. See page 12
Refer to
Service
- Auger Drive Com-
ponents. See page 12
Refer to
Service
- Auger Drive Com-
ponents. See page 12
Refer to
Service -
Rinse/Run Switch
for test procedures. See page 25
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
28364 041598