System Control Panel

The home generator control panel, located inside the

generator housing, is shown below.

Brief descriptions of the controls used during installation are:
A - Set Exercise Switch — Used to set the exercise cycle.
B - System Switch — Switches modes to OFF and AUTO.
C - 5 Amp Fuse — Protects the DC control circuits.
D - Service Tool — For qualified service personnel ONLY.
E - Digital Display — Displays running time and fault codes.
F - Circuit Breaker — Must be ON to supply power to the

transfer switch.

G - Manual Over-Ride Switch — Turns generator ON or OFF.
More information may be found in Controls in the Operator’s

Manual.

System Switch
This two-position switch is the most important control on

the home generator and is used as follows:
• “AUTO” position is the normal operating position. If

a utility power outage is sensed, the system will start

the generator. When utility power is restored, lets the

engine stabilize internal temperatures, shuts off the

generator, and waits for the next utility power outage.

• “OFF” position turns off running generator, prevents

unit from starting and resets any detected faults.

15 Amp Fuse
Protects the home generator DC control circuits. If the fuse

has ‘blown’ (melted open) or was removed, the engine

cannot crank or start. Replace the fuse using only an

identical ATO 5A fuse. One spare fuse is supplied with the

unit.

Final Installation Considerations

Engine Oil

NOTICE

Any attempt to crank or start the engine before it has been

properly serviced with the recommended oil will result in

equipment failure.

Refer to Maintenance and engine manual for oil fill

information.
Damage to equipment resulting from failure to follow this

instruction will void engine and generator warranty.

This engine is shipped from the factory pre-run and filled

with synthetic oil (API SJ/CF 5W-30W). This allows for

system operation in the widest range of temperature and

climate conditions. Before starting the engine, check oil level

and ensure that engine is serviced as described in the engine

operator’s manual.
NOTE: The use of synthetic oil does not alter the required oil

change intervals described in the engine operator’s manual.

Battery
The home generator is supplied with a sealed, valve-

regulated, lead-acid rechargeable 2 Volt DC, AGM type,

55 Amp-Hour battery. The battery cables are connected

at the factory. The unit’s 5 Amp fuse, which isolates

the battery and prevents the unit from starting, has been

removed for shipping. The battery will lose some charge

prior to installation of the generator. If battery voltage

is below 2 Volts, charge the battery. See Battery in the

Operator’s Manual Maintenance section for details.
IMPORTANT: If battery voltage is below 5 Volts, it may not

take a charge and you will need a new battery.

Fuel Supply System

Ensure that all fuel pipe connections are tight, secure and

without leaks.
Ensure that all gas line shutoff valves are OPEN and that

adequate fuel pressure is available whenever automatic

operation is desired.

B

A

C

D

F

G

E