beautypg.com

Briggs & Stratton 18000 User Manual

Page 14

background image

2

BRIGGSandSTRATTON.COM

Generator AC Connection System

A single-phase, three-wire AC connection system is used in

the home generator. The stator assembly consists of a pair

of stationary windings with two leads brought out of each

winding. The junction of leads 22 and 33 forms the neutral

lead, as shown schematically and as wiring diagram below. A

complete schematic and wiring diagram can be found in the

separate illustrated parts list manual.

NOTE: Neutral is not bonded to ground at generator.

Grounding the Generator

Ground the home generator per applicable codes, standards,

and regulations. The generator GND lug is located inside the

control panel door under the circuit breaker cover.

Utility Circuit Connection

“240V Utility” leads must be routed in conduit. The

“240V Utility” leads deliver power to the generator’s circuit

board, optional battery warmer and optional oil warmer. This

power also charges the battery. When power on these leads

is lost, the generator will start.
Using provided 2 pole connector plug and installer-supplied

minimum 300V, 4 AWG copper wire, connect each control

circuit terminal in the generator to the two-amp fuse

terminals in the automatic transfer switch.

Fault Detection System

The generator may have to run for long periods of time with

no operator present. For that reason, the system is equipped

with sensors that automatically shut down the generator in

the event of potentially damaging conditions, such as low

oil pressure, high oil temperature, over speed, and other

conditions. Refer to Fault Detection System in the Operator’s

Manual for more detailed information.
The owner will use the remote LED indicator to observe the

status of the home generator system. Consult with the owner

for a convenient location. To install the remote LED indicator:
. Push the LED through the mounting plate from the

front until it snaps in place.

IMPORTANT: The LED is polarity sensitive.
2. Using provided 0 pole connector and installer-supplied

minimum 8 AWG wire, connect the remote LED to the

generator control board. Use wire nuts to attach wire to

LED leads.

3. Attach mounting plate to installer-supplied electrical

box.

This manual is related to the following products: