4
2.2
V80 PDI-2 OPTICALLY ISOLATED INPUT MODULE
MODULE TYPE
PDI-2A PDI-2B
NUMBER OF INPUTS
:
16
16
INPUT VOLTAGE RANGE:
5-24 100-130 AC/DC
MAXIMUM INPUT CURRENT:
50ma
20ma
MINIMUM TURN ON CURRENT:
8ma
8ma
MAX TURN ON TIME:
1ms
1ms
MAX TURN OFF TIME:
1ms
1ms
VOLTAGE ISOLATION:
500V
500V
(Input to Input and Input to ground)
POWER REQUIREMENTS:
+5VDC, 40 ma typical (provided by
M16/M8 pwr supply)
DEBOUNCE TIME:
0 to 60000 ms (software selectable)
ENVIRONMENTAL:
Operating temperature range:
0
o
to 70
o
C
Storage temperature range:
-40
o
to 85
o
C
Humidity:
5% to 95% non-condensing