(b) Chimney pipe height is at least 2 feet higher than any part of the roof within 10 feet of

the chimney. (See Figure 12.)


4. Next, install a New Buck Corporation chimney connector to the flue of the heater or use 3

“ELL” brackets and secure to the top of the heater and pipe.


5. Using single wall chimney connector, connect the heater to the chimney by following

manufacturer's installation instructions exactly. (See Figure 13.)






















Figure 13

FINAL CHECK

1. Recheck the specified clearances.

2. Remove all foreign material from the firebox area.

3 . Open the primary air draft.

NOTE: Plug the power cord into a 115 VAC outlet. Route the cord to prevent damage to the
cord insulation from heat and sharp objects. Keep the cord out of the way of traffic to prevent
damage caused by tripping, etc.

CEILING SUPPORT BOX

SINGLE WALL PIPE

CHIMNEY CONNECTOR