GAS BURNERS DATA TABLES
Models X304PIRX
[M7S0PTU(4,6)X(2,5)D]
Models X304PIRBI
[M7S0PTU(4,6)W(2,5)D]
Models X304PIRCR
[M7S0PTU(4,6)D(2,5)D]
Models X304PIRGI
[M7S0PTU(4,6)I(2,5)D]
Models X304PIRRO
[M7S0PTU(4,6)R(2,5)D]
Models X304PIRVI
[M7S0PTU(4,6)L(2,5)D]
Models X304PIRVE
[M7S0PTU(4,6)V(2,5)D]
Models X304PIRBL
[M7S0PTU(4,6)U(2,5)D]
Models X304PIRNE
[M7S0PTU(4,6)N(2,5)D]
Burner Position Injector Gas Pressure
Max Rate
Min Rate
By‐pass
diam.
[mm.]
Type
[i.w.c.]
[BTU/h]
[W] [BTU/h]
[W] diam.
[mm]
Auxiliary
Rear L
0,90
NG
4”
3400
996
900
264
Regulated
0,54
LP
(Propane)
11”
3400
996
900
264
0,29
Semi‐Rapid Front
R
1,18
NG
4” 6100
1787
1500 439 Regulated
0,70
LP
(Propane)
11”
6100
1787
1500
439
0,36
Rapid Rear
R 1,55 NG 4”
10400
3047
2500
732
Regulated
0,92
LP
(Propane)
11”
10400
3047
2500
732
0,47
Front L Inner
0,80
NG
4”
2800
820
900
264
Regulated
Dual Burner
0,49
LP (Propane)
11”
2800
820
900
264
0,29
Front L Outer
N°2 x 1,15
NG
4”
12000 3516
4500
1318
Regulated
N°2 x 0,70
LP (Propane)
11”
12000 3516
4500
1318
0,65