beautypg.com

Bunn CWTF TWIN-APS User Manual

Page 10

background image

Page 10

TROUBLESHOOTING (cont.)

PROBLEM

Inconsistent beverage level in dis-
penser

Consistently low beverage level in
the dispenser

Spitting or excessive steaming

PROBABLE CAUSE

1. Strainer/flow control (.222
GPM)

2. Syphon System

3. Lime Build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can
initiate corrosive reactions result-
ing in serious leaks.

4. Water Pressure

1. Timer

2. Strainer/flow Control (.222
GPM)

1. Lime Build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can
initiate corrosive reactions result-
ing in serious leaks.

REMEDY

(A) Direction of flow arrow must
be pointing towards the brewer.

(B) Remove the strainer/flow con-
trol and check for obstruction.
Clear or replace.

The brewer must be level or slightly
lower in front to syphon properly.

Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.

The water pressure to the brewer
must be at least 20 psi (138 kPa).

(A) Early Models - Timer dial must
indicate at least two minutes and
fifteen seconds.

(B) Late Models - Refer to

Service

-

Digital Timer for testing proce-

dures. See page 25

(A) Direction of flow arrow must
be pointing towards brewer.

(B) Remove the strainer/flow con-
trol and check for obstructions.
Clear or replace.

Inspect tank assembly for exces-
sive lime deposits. Delime as re-
quired.

10737 120800