beautypg.com

2appliance details – Bosch AQUA STAR 250SX LP User Manual

Page 4

background image

6 720 607 057

4

Appliance details

2

Appliance details

2.1

Features

Parts

• Touch Pad interface control

• High power pre-mix compact burner with low Nox

emissions

• Modulating Gas Valve with constant gas:air ratio

control

• Modulating water valve for improved comfort and

temperature control.

Safety

• Flame sensor (ionization) rod

• Overheat sensor

• Temperature limiter

• Fan speed monitoring.

High Quality Materials for Long Working Life

• Copper heat exchanger

• Ceramic Burner output

• Automatic overheating protection shut-off sensor

• Compact space saver: mounts on a wall with a

supplied bracket.

• Easily removable one-piece cover.

Features

• LCD Display

• On/Off and Temperature control switches

• Reset button

• Program Key (Selectable temperature default)

• Failure codes for easy diagnostic and repair.

Accessories

• Optional wireless remote control accessory to

operate with the appliance

• Vent termination kit.

2.2

250 SX Specifications (Technical
data)

Approved in US/Canada

Capacity

Maximum flow rate: 6.35 GPM (24 l/min) at a 45°F
(25°C) rise.

Maximum output

142,968 Btu/h (41.8 kW)

Maximum input

175,000 Btu/h (51.2 kW)

Efficiency in %

Recovery efficiency 86.5%

Min. Output

31,131 Btu/h (9.1 kW)

Temperature Control

Selection range: 100°F (38°C) - 140°F (60°C)

Default temperature: 122°F (50°C)

Stability: +/- 2°F (+/- 1°C)

Gas Requirement

Gas connection (inches) - ¾”

Inlet gas pressure under operation (with a high hot
water flow rate)*

• Propane: 11” - 14” water column

• Natural Gas: 5” - 14” water column

• Gas pressure measuring point inside the appliance

at the gas valve inlet.

* Testing with a manometer, operate other gas
equipment on the same gas supply. Gas pressures
lower than 5" W.C. for Natural Gas or 11" W.C. for
LPG will result in insufficient degree rise to the hot
water being used. See Measuring Gas Pressure,
chapter 2.12.

Fig. 3

Gas pressure measuring point

Venting

See chapter 2.9 for Venting on page 9.

Water

• Hot water connection (inches) - ¾”

• Cold water connection (inches) - ¾”

• Water valve material: Polymer (PPS) (Polypropylene

Sulfid)

• Minimum water flow: 0.8 gallon/minute (3 l/m)

i

BOSCH is constantly improving its
products, therefore specifications are
subject to change without prior notice.

This manual is related to the following products: