Troubleshooting

Display

Cause

Solution

E9

Temperature limiter opened circuit
(overheat). Trips at 220F (104C).

Check connections.*
Check heat exchanger condition.*

EA

No ionization during safety time (safety time
out).

Check gas pressure.*
Check that gas is not diluted with air, as a result
from recent gas pipeline rework.*.
Check if vent terminal is blocked (especially when
the appliance starts up for some seconds and then
looses ionization signal).*
Check ionization electrode.*
Check for a proper ground.*

EC

The ionization signal momentarily
disappeared more then 3 times in less then
30 seconds.

FA

Leakage error (gas valves do not close gas
circuit).

Check gas valve and control unit.*

F7

Ionization error (flame sensing at stand-by).

Check control unit.*

E0

Internal software/hardware failure.

Check control unit.*

A7

Hot water temperature sensor/receiver
defect (from control unit).

Check water temperature sensor/receiver and
connections.*
Check room area temperature where heater is
located, it must be above 36°F (2°C)

A9

Hot water temperature sensor/receiver mis-
assembled (from control unit).

Check that the water temperature sensor/receiver is
properly assembled in the water pipe.*
Check if vent terminal is blocked or if vent terminal is
according with

chapter 2.9

.*

In case of high altitude installation confirm that
necessary adjustment steps have been taken.*

C1

FAN rotation too low at start-up (from
control unit).

Check supply voltage.*
Check fan and connections.*
Check control unit.*
Check if vent terminal is blocked or if vent terminal is
according with

chapter 2.9

. *

Check CO

2

levels (see chapter

9

).*

C6

FAN rotation too low at operation (from
control unit).

Check supply voltage.*
Check fan and connections.*
Check control unit.*
Check if vent terminal is according with

chapter 2.9

.*

C7

No rotational speed sensor signal from FAN

Check fan and connections.*
Check control unit.*
Check CO

2

levels (see chapter

9

).*

CA

Water flow signal over specified maximum
value

Check water valve and flow sensor.*

E2

Inlet temperature sensor fault

Check water temperature sensor/receiver and
connections.*
Check room area temperature where heater is
located, it must be above 36°F (2°C)

A2

Overheat protection fault

Check connections to the overheat protection.*
Check sensor continuity.*
Check heat exchanger sealings and walls.*

Table 5

* By installer or service technician only.