Special adjustment for measuring and adjusting CO2 levels

9

Special adjustment for measuring and adjusting CO

2

levels

The CO

2

can only be adjusted by a certified gas

technician with a calibrated CO

2

analyzer.

9.1

Adjusting the unit

Factory settings of this appliance are listed in table 7.
Further adjustment is only needed if optimal CO

2

level

is required in order to assure the minimum possible
CO

2

emissions. In this case a CO

2

analyzer is required.

9.1.1

CO

2

measuring

B Loosen screw 1 (Fig. 41).

B Insert CO

2

analyzer into measuring port (Fig. 41,

pos. 1).

Fig. 41

1

Measuring point

9.1.2

Selecting adjustment mode

B ON/OFF switch in position OFF (0).

CO

2

adjustment at minimum gas flow (P2) - See

table 7.

B Press “Program” key and turn ON/OFF switch to

position ON.

Fig. 42

LCD shows “P2” and the appliance is ready to be
adjusted.

B Open hot water tap.

The appliance will run constantly at minimum power
output and minimum water flow. This program step can
also be used to measure minimum output and minimum
water flow.

B Turn the screw in order to regulate the air-gas mixture

inside the ventilator until the CO

2

level required is

reached (Fig. 43, pos. 3).

CO

2

adjustment at maximum gas flow (P1) - See

table 7.

B Press

, until “P1” appears.

B Open hot water tap.

The appliance will run constantly at maximum power
output and maximum water flow. This program step can
also be used to measure maximum output and maximum
water flow.

B Turn the screw in order to regulate the air-gas mixture

inside the ventilator until the CO

2

level required is

reached (Fig. 43, pos. 3).

Caution: Converting the gas type can
only be done by a certified gas
technician with a calibrated CO

2

analyzer. Call CEC for conversion
instructions.

Caution: Adjustments must only be
carried out by authorized service
personnel only.

Caution: The appliance should always
be disconnected from the power supply
before any maintenance is carried out.

Factory
setting

Field settings
acceptable range

Nat. Gas

Nat. Gas

max. input

P1

9.50 %

8.00 % to 10.00 %

min. input

P2

9.50 %

8.00 % to 10.00 %

LP Gas

LP Gas

max. input

P1

10.50 %

10.00 % to 11.00 %

min. input

P2

10.50 %

10.00 % to 11.00 %

* Final reading must be confirmed with the front cover
on, CO

2

levels increase when the cover is installed.

Table 7