Installation (continued), Warning, Shock hazard – Bloomfield 8740 User Manual
Page 7
INSTALLATION (continued)
5
WARNING
SHOCK HAZARD
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT assume
a plumbing line will provide such
a ground. Electrical shock will
cause death or serious injury.
IMPORTANT:
Supply power must match
nameplate for voltage and phase.
Connecting to the wrong voltage
will damage the brewer or result
in decreased performance.
Such damage is not covered by
warranty.
IMPORTANT: The ground prong
of the plug is part of a system
designed to protect you from
electrical shock in the event of
internal damage. Never cut off
the ground prong nor twist a
blade to fit an existing receptacle.
Contact a licensed electrician to
install the proper circuit and
receptacle.
IMPORTANT: Do not connect
brewer to electrical power until
you are ready to fill the tank.
See instructions at left.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT: Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Model 8740 is equipped with a cord and plug.
It requires a 115 - 125 volt 20 amp circuit (50/60 Hz, 2 wire plus
ground, with NEMA 5-15R receptacle).
PREPARATION
The water tank must be filler prior to operation. Slide an empty
brew chamber in place under the brew head. Place an empty
dispenser under the brew chamber.
Be sure the unit is connected to the water supply, the water
supply is turned ON and the "TANK HEATER SWITCH" is OFF.
Connect the unit to electric power.
Press the "START BREW" switch to initiate a brew cycle. The
solenoid will open and begin filling the tank. Initiate consecutive
brew cycles until water begins to flow from the brew head.
When all water stops dripping, discard all water generated.
Press the "TANK HEATER SWITCH" to ON. The heating
elements will begin heating the water in the tank. When the
"READY TO BREW" light glows the unit is ready for use.
NEMA 5-15R
RECEPTACLE
NEMA 5-15P
PLUG
GROUND
PIN
Fig. 3 Plug Configuration
608
p/n
7646
7 874
0 Tea B
rewer
Owners M
anual