Troubleshooting suggestions – Bloomfield 8740 User Manual
Page 12
TROUBLESHOOTING SUGGESTIONS
SUGGESTED REMEDY
Check power supply cord
Check / reset circuit breaker
Press switch to ON
Set for desired temperature
Allow to cool hi-limit will self-
reset
Examine wiring & connectors,
controller, power board and
heating element
Repair/replace as needed
Adjust timer
Use one (1) genuine Bloomfield
filter per brew
Thoroughly clean brew
chamber
Use correct amount of tea
Check/reinstall gasket on
INSIDE of brew head
Clean spray disk
Check switches, timer and
solenoid.
Repair, replace as needed
Turn water supply ON
Clean strainer
Replace filter element
POSSIBLE CAUSE
Brewer unplugged or circuit
breaker tripped
Tank heater switch OFF
Temperature setpoint too low
Hi-Limit safety switch tripped
Damaged internal component
or wiring
Timer out of adjustment
Too many filter papers or wrong
filter paper
Brew chamber dispense hole
plugged
Too much tea leaves
Spray gasket improperly
installed
Spray disk plugged
Damaged internal component
or wiring
Water supply OFF
Solenoid inlet strainer plugged
Water filter (if used) plugged
SYMPTOM
Water won’t heat
Tea level too high or low
Brew chamber overflows
Sprays water from brew head
No brew
Poor tea quality
Keep brewer and dispenser clean.
Install a taste and odor filter in water supply, and replace
cartridges regularly.
Use a quality fresh supply of tea leaves. Use amount of tea
leaves appropriate to brew volume.
10
608
p/n
7646
7 874
0 Tea B
rewer
Owners M
anual