Servicing instructions caution, Shock hazard – Bloomfield 8740 User Manual
Page 13
SERVICING INSTRUCTIONS
CAUTION:
SHOCK HAZARD
Opening access panels on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel.
NOTE ;
Time and temperature controls
may be accessed without
removing cabinet panels by
removing the appropriate hole
plug from the top wrap.
ACCESS PLUGS
Use a small flat-blade screwdriver or similar implement to pry the
hole plug from the access hole in the top wrap.
HOT WATER TEMPERATURE:
Remove right 7/8" hole plug to access temperature control.
WATER DELIVERED VOLUME:
Remove left 2" hole plug to access water volume timer.
ACCESS PANELS
TOP WRAP:
Remove top wrap to access hot water tank, thermostat, timer,
switches and brew circuit tubing.
Top wrap is held by two screws at the front and two screws at
the rear.
REAR PANEL:
Remove rear panel to access wiring and brew solenoid.
Rear panel is held by two screws and a retaining lip.
Fig. 8 Access Panels
11
608
p/n
7646
7 874
0 Tea B
rewer
Owners M
anual