beautypg.com

Bunn Dual TF DBC With Smart Funnel DUAL068000 User Manual

Page 8

background image

Page 8

INITIAL SETUP

CAUTION – The brewer must be disconnected from the power source throughout the initial setup, except when

specified in the instructions.

1. Insert an empty funnel into the funnel rails of one of the

brew stations.

2. Place an empty server under the funnel.

3. Connect the brewer to the power source. Main ON/OFF

Switch (located in bottom cover behind front leg on some

brewers) must be in the ON position. Water will begin

flowing into the tank and stop when the tank is filled to its

capacity. Display will show PLEASE WAIT...TANK FILLING

until tank is filled with water.

4. Wait approximately twenty minutes for the water in the

tank to heat to the proper temperature. Display will show

READY TO BREW...WATER TEMP: XXX˚ when tank is at

operating temperature.

NOTE: Brew water temperature is factory set at 205° F

(96.1° C). Refer to TEMPERATURE SELECTION below

should the water temperature need to be increased or de-

creased. When brew water temperature is changed, ready

temperature should be increased or decreased accordingly.

5. Place a small vessel beneath the faucet and open the faucet

handle. Release it when you hear the tank refilling.

6. Water volumes have been preset at the factory. Refer to

adjustments for the Set Brew Volumes section of the Pro-

gramming Manual on the Bunn-O-Matic website, at www.

bunn.com should the volume need to be increased or decreased.

7. The brewer is now ready for use in accordance with the coffee brewing instructions.

TEMPERATURE SELECTION

SET TEMP - Range: 185˚F (85˚C) to 205˚F (96˚C)

This function allows the operator to set the brew water temperature in the tank. It also sets the hot water

faucet dispense temperature.

Procedure to set brew temperature:

1. Press and hold upper right hidden switch until the display reads UNITS. Release switch. Continue to press

and release switch until the display reads SET TEMP.

2. To adjust the brew temperature, press (-) to decrease or (+) to increase the brew temperature.

3. When finished, press and release DONE to save the new setting, exit the SET TEMP function and advance to

the next function screen, SET READY. Another alternative is to press and release the ON/OFF switch (either

on DUAL brewers) located on the front switch panel to exit the SET TEMP function and return to the MAIN

SCREEN.

35058.2 111611

°

°

°

°

SET TEMP: XXX°

(-) DONE (+)