ELECTRICAL REQUIREMENTS (Models with power cord)

WARNING - The brewer must be disconnected from the power source until specified in Initial Set-Up.

Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.

To reduce the risk of electric shock,

do not remove or open cover.

No user-serviceable parts inside.

Authorized service personnel only.

Disconnect power before servicing.

USER NOTICES (cont.)

37881.0002

GREEN

GREEN

L1, L2, L3, are the 3 phases

V1 = Phase to phase voltage, between any 2

phases.

V2 = Phase to neutral voltage, L1 to neutral

must be 120V.

SYSTEM

VOLTAGE

V1

V2

208

208 120

240

240 120

CAUTION: Do not connect L1 to a circuit

operating at more than 150 volts to

ground.

120/208 and 120/240 volt ac

3 phase & multi phase,

60 Hz models

Note: This electrical service

consists of 4 current carrying

conductors (Neutral, L1, L2

and L3) and a separate con-

ductor for earth ground.

400/230V ac

3 phase models

Note: This electrical service

consists of 4 current carrying

conductors (Neutral, L1, L2

and L3) and a separate con-

ductor for earth ground.

GREEN

GREEN

BLK

RED

BRN

BLU

L1

L2

L3

N

WHI

BLK

RED

BLU

L3

L2

L1

N

SYSTEM

VOLTAGE

V1

V2

400/230

400

230

L1, L2, L3, are the 3 phases

V1 = Phase to phase voltage, between

any 2 phases.

V2 = Phase to neutral voltage, between

neutral and any phase.

120/208 and 120/240 volt ac

multi phase, 60 Hz models

Do NOT connect an external neu-

tral to this brewer.

Note: This electrical service con-

sists of 3 current carrying conduc-

tors (L1, L2 and L3) and a separate

conductor for earth ground.

GREEN

GREEN

L1 BLACK

L1 BLACK

L3 BLU

L3 BLU

L2 RED

L2 RED

35058.2 022410