Selecting a chimney installation and location – New Buck Corporation 20 Room Heater User Manual
Page 49
F. DO NOT build a fire directly inside the ZC Cabinet. It is designed solely for housing the Model 20 Stove.
G. WARNING: This fireplace has not been tested for use with a chase above the roof.
H. Do not connect this unit to a chimney serving another appliance.
SELECTING A CHIMNEY INSTALLATION AND LOCATION
There are two basic types of chimney installations possible with the ZC20; straight up through a ceiling, and chase
installation, either outside or inside. These are normally used as follows:
FIGURE 1 THROUGH CEILING
FIGURE 2 THROUGH CATHEDRAL
CEILING
FIGURE 3 OFFSET TO CLEAR OBSTRUCTION
CAUTION: Refer to chimney
manufacturers instructions for assembly
and disassembly of chimney parts. Be sure to
follow chimney instructions for proper clearances
to combustibles and proper air spacing required.
STORM COLLAR
FLASHING
CHIMNEY PIPE
METAL FIRE STOP
METAL FIRE STOP
Z.C. CABINET
CHIMNEY CAP
CHIMNEY CAP
CHIMNEY PIPE
STORM COLLAR
FLASHING
METAL FIRE STOP
Z.C. CABINET
CHIMNEY CAP
CHIMNEY PIPE
STORM COLLAR
FLASHING
ELBOWS
ADJUSTABLE CHIMNEY
METAL FIRE STOP
Z.C. CABINET