and door to rake the wood and coals into a pile near the front center of the firebox. (Be certain wood

chunks are pulled out of the rear corners.) Close door and bypass damper. This step will assure continued

combustion and thorough burning of the wood.

D. High-Burn Rate—Set primary air control wide open. . Set the Auto-Off-Manual switch to the Auto

position. Wood Loading—During refueling, open the bypass damper, open the door, and add wood.
Immediately close door and bypass damper.


NOTE: To select primary air setting, center rod where it exits the air vent opening and align to the marked settings
on the heater.








































You will have to experiment with the rate until you find the particular setting for heating your home. Chimney
drafts, tightness of the house doors and windows, and atmospheric conditions all influence which setting you must
have so it may take you several firings to learn the setting necessary for your installation.

Although the catalytic heaters decrease ash residue, routine removal of excess ash is still necessary.

Align where handle rod exits face of air vent

High

Mid. High

Mid. Low

Low