SERVICING INSTRUCTIONS (continued)
13
REPLACE HEATING ELEMENT
 
Remove tank lid assembly per above. 
 
Remove two hex nuts holding element to cover. Pull element 
from mounting holes. 
 
Reassemble in reverse order. 
 
REPLACE WARMER ELEMENT 
 
Remove warmer plate by turning counter-clockwise. 
 
Lift element from bracket. Disconnect wiring. 
 
Reassemble in reverse order. 
 
REPLACE SOLENOID 
 
Symptom: brewer will not flow water; or, brewer drips 
continuously from brew head.) 
 
Unplug power cord or turn circuit breaker OFF. Turn OFF and 
disconnect water supply from brewer inlet fitting. 
 
Remove water bottle and top panel. 
 
Cut tie straps from solenoid hose connections. Remove wiring 
connections from solenoid coil. Remove solenoid 
 
Reassemble in reverse order. 
 
REPLACE TIMER ASSEMBLY 
 
Unplug power cord or turn circuit breaker OFF. 
 
Remove front panel. Remove knob and three screws holding 
timer to bracket. Disconnect wiring to timer. 
 
Reassemble in reverse order. 
Adjust timer as described on page 12. 
 
REPLACE BREW READY LIGHT, BREW SWITCH OR 
WARMER SWITCH 
 
Unplug power cord or turn circuit breaker OFF. 
 
Remove water bottle, top panel and basin pan. 
 
Using Switch Removal Tool (p/n 83209) or a thin screwdriver, pry 
light or switch from mounting hole. Disconnect leads. 
 
Reassemble in reverse order. 
IMPORTANT: When replacing 
heating element, also replace 