DIP shunt E4 selects the pin out for the DB25 connector P3. With the
5-position shunt in the EIA-530 mode, the RS422/485 Serial Interface Plus
complies with the EIA-530 pinout with the following signals supported:
Signal
Name
Pin #
Mode
GND
Ground
7
RDB
RX+
Receive Positive
16
Input RS-422
RDA
RX
Receive Negative
3
Input RS-422
CTSB
CTS+
Clear To Send Positive
13
Input RS-422
CTSA
CTS-
Clear To Send Negative
5
Input RS-422
DSRB
DSR+
Data Set Ready Positive
22
Input RS-422
DSRA
DSR-
Data Set Ready Negative
6
Input RS-422
DCDB
DCD+
Data Carrier Detect Positive
10
Input RS-422
DCDA
DCD-
Data Carrier Detect Negative
8
Input RS-422
TDB
TX+
Transmit Positive
14
Output RS-422
TDA
TX-
Transmit Negative
2
Output RS-422
RTSB
RTS+
Request To Send Positive
19
Output RS-422
RTSA
RTS-
Request To Send Negative
4
Output RS-422
DTRB
DTR+
Data Terminal Ready Positive
23
Output RS-422
DTRA
DTR-
Data Terminal Ready Negative
20
Output RS-422
Figure 4-10. DIP Shunt E4 (SIO-485 Mode).
With the 5-position shunt in the SIO-485 mode, the RS422/485 Serial
Interface Plus converts to 4-wire or 2-wire RS-422/485 with the following
signals supported:
EIA-530
SIO-485