beautypg.com

B&B Electronics RS-232 to J1939 Converter CE 1939STB User Manual

Page 11

background image

1939STB4600 Manual

9

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445

RS-232 Baud Change

Setting byte-3/nibble-2 to 2 and byte-4/nibble-1 to 2 causes the 1939STB

to change baud. This function also requires 3 bytes of additional information
bytes 5, 6, and 7. It is important to note that after a baud change the PC must
have its baud changed to match the baud of the 1939STB for communication
to exist. If communication is lost after a baud change and cannot be
recovered, disconnecting the 1939STB from its power source will restore the
1939STB to its default baud rate of 9600 baud, 1 stop bit, 8 data bits, no
parity.

Table 11. Baud Rate Setup

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte
1

Byte
2

Nibble 2

Nibble 1

Nibble 2

Nibble 1

UB3

Baud 1

Baud 2

81

21

0010 0011

0000

0010

81

21

23 hex

02 hex

03 hex

00 hex

06 hex

Table 11 shows how an internal command is used to set the 1939STB to a

baud rate of 300, 1 stop bit, 8 data words, and no parity. Byte 3 nibble 2 sets
the internal command function. A nibble value of 2 sets the J1939STB into
the Internal Function mode. Nibble 1 of byte 3 tells the 1939STB 3 bytes will
follow Byte 4. Byte 4, nibble 1 is set to 2 telling the 1939STB to perform a
baud change using the information contained in bytes 5, 6, and 7.

Table 12. Baud Rate Setup

Baud Rate

Decimal Divisor

Hex Divisor MSB (Baud 2)

Hex Divisor LSB (Baud 1)

300

1556

06 hex

00 hex

1200

384

01 hex

80 hex

2400

192

00 hex

C0 hex

9600

48

00 hex *

30 hex *

19200

24

00 hex

18 hex

38,400

12

00 hex

0C hex

57,600

8

00 hex

08 hex

* Setup default value.