Configure the following connection details in the, View of the, Window – Barracuda Networks VERSION SP4 User Manual
Page 109

107 Barracuda NG Network Access Client - Administrator’s Guide
Configure the following connection details in the
Advanced
view of the
Rule Object
window:
List 9–6 Edit/Create Rule Object - Options in the Advanced view – section Rule Mismatch Policy
Parameter
Description
Source / Service/ Destination /
Application / User / Adapter
• Continue on Mismatch (default)
Process the rule, even if the corresponding object does not match the configured setting.
• BLOCK on Mismatch
Do not process the rule if the corresponding object does not match the configured setting.
List 9–7 Edit/Create Rule Object - Options in the Advanced view – section Miscellaneous
Parameter
Description
Time Restriction
A time restriction can be assigned to each rule. The granularity is 1 hour on a weekly base.
A rule is allowed at all times by default, for example, all checkboxes in the
Time Interval
window are cleared. Selecting
a checkbox denies a rule for the given time.
Select
(set invert) from the list to configure allowed and disallowed time intervals simultaneously.
Select
(set allow) from the list to clear selected checkboxes.
Select
(set deny) from the list to to configure disallowed time intervals.
Select
Continue if mismatch
to process the rule even if time restriction denies it.
Select
Block if mismatch
to prevent rule processing if time restriction denies it (default).
Monitor Connections
• Yes
• No
Fig. 9–18 Time restriction dialog