NOTICE

Any attempt to crank or start the engine before it has been

properly serviced with the recommended oil will result in

equipment failure.

Refer to Maintenance and engine manual for oil fill

information.
Damage to equipment resulting from failure to follow this

instruction will void engine and generator warranty.

To fill your engine with oil:
Follow the synthetic oil grade recommendation and oil fill

instructions given in the engine operator’s manual.

Battery

Charging the Battery
If it is necessary to charge the battery, proceed as follows:
1. Set generator’s system switch to OFF.
2. Remove 15 Amp fuse from control panel.
3. Disconnect negative battery cable to negative battery

terminal (indicated by NEGATIVE, NEG, or (-).

NOTICE

Failure to disconnect negative battery cable will result in

equipment failure.

DO NOT attempt to jump start the battery.
Damage to equipment resulting from failure to follow this

instruction will void warranty.


4. Charge battery with battery charger at 2 Amps until

battery holds 12 Volts.

NOTE: DO NOT exceed 13.7 Volts charging.

WARNING

Storage batteries give off explosive hydrogen

gas during recharging.
Slightest spark will ignite hydrogen and cause

explosion.
Battery electrolyte fluid contains acid and is

extremely caustic.
Contact with battery contents will cause severe

chemical burns.
A battery presents a risk of electrical shock and

high short circuit current.

DO NOT dispose of battery in a fire.
DO NOT allow any open flame, spark, heat, or lit cigarette

during and for several minutes after charging a battery.
DO NOT open or mutilate the battery.
Wear protective goggles, rubber apron, and rubber

gloves.
Remove watches, rings, or other metal objects.
Use tools with insulated handles.




NOTE: With the battery installed and utility power available

to the transfer switch, the battery receives a trickle charge

whenever the engine is not running. It may take up to 72

hours to fully charge a battery from 5 Volts with the trickle

charge. The trickle charge is not able to recharge a battery

that is completely discharged.
5. Connect negative battery cable to negative battery

terminal (indicated by NEGATIVE, NEG, or (-)).

6. Ensure hardware on both positive and negative battery

terminals is secure.

7. Reinstall 15 Amp fuse in control panel.

CAUTION

Installing the 15A fuse could cause the engine

to start.

DO NOT install this fuse until all plumbing and wiring has

been completed and inspected.

8. Set generator’s system switch to AUTO.