beautypg.com

Bosch DSDA ISCSI DISK ARRAY SERIES DSA-S5B50 User Manual

Page 21

background image

DSDA iSCSI Disk Array Series

Adding Storage | en

19

Bosch Security Systems

Installation Guide

V 1 | 2008.08

6.1.3

Connecting the Shelf

4.

Connect the shelves using the supplied cables.

For the first shelf:

Insert an SFP into the In port of each of the two I/O modules at the back of the shelf

to convert them to optical ports, making sure that the SFP has the correct position

before inserting it.

Plug in one end of the optical cable to the In port of the lower I/O module on your

shelf.

Plug the other end into the Fibre Channel (FC) port labeled 0a on the storage con-

troller.

Connect one end of the second optical cable into the In port of the upper I/O mod-

ule of your shelf.

Connect the other end to the second FC port on your storage system, labeled 0b.

For additional shelves:

Insert an SFP into the In port of each of the two I/O modules at the back of the shelf

to convert them to optical ports, making sure that the SFP has the correct position

before inserting it. Repeat this for the Out port of the last shelf in your existing loop.

Connect one end of the SFP-SFP cable to the In port of the upper I/O module in your

new disk shelf.

Connect the other end to the Out port of the upper I/O module of the last shelf in

your existing loop.

Connect one end of the SFP-SFP cable to the In port of the lower I/O module in your

new disk shelf.

Connect the other end to the Out port of the lower I/O module of the last shelf in

your existing loop.

5.

Log in to the FilerView administration interface as described in Section 5 Configuration

through the Web Interface, page 8.

6.

In the navigation panel, select Storage > Disks > Manage and verify that the system

shows the new disks, i.e. View Type is set to Spare Disks.

6.1.4

Adding New Volumes

7.

In the navigation panel, select Volumes > Add.

Click Next in the welcome screen of the Volume Wizard.

8.

Volume Type Selection: Set to Traditional. Click Next.

i

NOTICE!

It might take up to 60 seconds for the storage system to recognize the new disks.

The procedure as described above is only valid for new disk shelves. If you want to assign disk

shelves that have already been used by a different storage controller, please refer to the

original NetApp documentation.

i

NOTICE!

If you are using the VRM Video Recording Manager application (Version 1.5 or higher), all

further settings are made through VRM.

If you use the digital storage systems for direct recording, continue with the following steps.

This manual is related to the following products: