Troubleshooting guide, Problem cause solution – Boston Acoustics LCAi220 User Manual
Page 16
TroubleShooting Guide
Problem
Cause
Solution
No Power
• Local power supply is off or
disconnected
• Central power supply is off or
disconnected
• Check / connect local power
supply
• Check / connect central power
supply and rear connection to
LCAi220
No Sound
• Speaker wires are disconnected
• Volume is adjusted too low
• Source is off / disconnected
• Connect speaker wires
• Adjust source volume
• Check source connections and
power status
No Audio From Local
Zone
• Source not configured correctly
• Connections to LCAi220 are not
made correctly
• Check local source
• Check all connections.
No Audio in Bypass Mode
• Central music system is not on /
configured correctly
• Connections to LCAi220 are not
made correctly
• Configure central audio system
• Check all connections
Fault Light is On
• DC detected at speaker leads
• Check all wiring and
connections
Fault Light Flashes Once
Per Second
• Short circuit detected at speaker leads
• Check all wiring and
connections
• Make Sure load to the amplifier is 4
Ω
or
higher
Fault Light Flashes Once
Every Two Seconds
• Thermal - the amplifier has overheated.
• Check all wiring and
connections
• Make Sure load to the amplifier is 4
Ω
or
higher
Local zone;
distortion at higher
volumes
• Gain on the LCAi220 is too high,
volume is up to high on the
local source
• Lower gains / volume levels on
the LCAi220 and local source
15
Warning: Always disconnect power to the LCAi220 and shut down any connected devices before
making/checking any front or rear connections on the LCAi220.