beautypg.com

Warning, Electrical connection, Gas connection – Bosch WTMC 652SUC User Manual

Page 8

background image

8

Electrical connection

GROUNDING INSTRUCTIONS
This appliance must be grounded.

In the event of a malfunction or

breakdown, grounding will reduce

the risk of electrical shock by

providing a path of least resistance

for the electric current.

This appliance features a cord with

an equipmentĆgrounding conductor

and a grounding plug. The plug

must be plugged into an

appropriate outlet which has been

properly installed and grounded in

accordance with all local

regulations and ordinances.

d

WARNING

d

Improper connection of the

equipment grounding conductor

may result in electric shock.

Have the appliance checked by

a qualified electrician or service

technician if you are in doubt as

to whether the dryer has been

properly grounded.

Do not modify the plug provided

with the appliance - if it will not fit in

the outlet, have a proper outlet

installed by a qualified electrician or

exchange the cord with an

appropriate one rated for the dryer.

d

WARNING

d

The dryer must only be

connected to an individual

branch circuit via a socket which

has been properly installed and

grounded.

The household electrical voltage

must correspond to the voltage

specification on the dryer (rating

plate).

You will find the rating plate on the

inside of the front panel.

Connection specifications as well

as the electrical requirements are

stipulated on the appliance

nameplate.
Make sure that:
- the power cord plug fits into the

socket.

- the power cord is acceptable

for use in this application.

- the grounding system is

properly installed.

The power cord may be replaced by

an electrician only.

Replacement power cords are

available from Customer Service.

Volts

Hertz

Amperes

Watts

110-120

60

9

1080

Gas connection

d

WARNING

d

Explosion hazard!
Use a new AGA or CSA

approved gas supply line.

Install a shutĆoff valve.

Securely tighten all gas

connections.

Have a qualified person make

sure gas pressure does not

exceed 14 in. W.C./ 3.49 kPa/

0.506 psig. (Natural Gas).

Example of a qualified person

include:

- licensed heating personnel,

- authorized gas supplier

personnel,

- authorized service personnel.

Failure to do can result in

explosion or fire.
Risk of death or injury!
All gas line connections must be

tested for leaks prior to

appliance operation. Apply

soapy water to gas line

connections and check for

formation of new bubbles.

Bubbles indicate leak!

When installing the gas supply to

the gas dryer inlet pipe, do not

exceed 310 lbf in (35 Nm).

d

WARNING

d

Never use an open flame to test

for gas leaks.

Gas type

This dryer when equipped for use

with NATURAL GAS will employ an

orifice size 46 and have a gas outlet

pressure of 3.5 in. W.C.
Your dryer must have the correct

valve for the type of gas in your

home. Valve information is located

on the rating plate behind the door

below the port hole.
If the ratingĆplate information does

not agree with the type of gas

available, contact your dealer or our

costumer service team

(see page 27).