beautypg.com

Warning, Electrical connection – Whirlpool WDE150LVS User Manual

Page 6

background image

6

Electrical Connection

This range is manufactured with a neutral (white) power supply
wire and a cabinet-connected green (or bare) ground wire twisted
together.

1. Disconnect power.

2. Remove junction box cover if it is present.

3. Install a UL listed or CSA approved conduit connector to the

junction box.

4. Route the flexible conduit from the range to the junction box

through a UL listed or CSA approved conduit connector.

5. Tighten screws on conduit connector.

6. See “Electrical Connection Options Chart” to complete

installation for your type of electrical connection.

Electrical Connection Options Chart

4-Wire Cable from Home Power Supply

IMPORTANT: Use the 4-wire cable from home power supply
where local codes do not allow grounding through neutral, New
Branch circuit installations (1996 NEC), mobile homes,
recreational vehicles, and new construction.

1. Connect the 2 black wires (B) together using a UL listed wire

connector.

2. Connect the 2 red wires (C) together using a UL listed wire

connector.

3. Untwist white wire from green (or bare) ground wire coming

from the range.

4. Connect the 2 white wires (F) together using a UL listed wire

connector.

5. Connect the green (or bare) ground wire (H) from the range

cable to the green (or bare) ground wire (in the junction box)
using a UL listed wire connector.

6. Install junction box cover.

3-Wire Cable from Home Power Supply

IMPORTANT: Use the 3-wire cable from home power supply
where local codes permit a 3-wire connection.

A. UL listed or CSA approved conduit connector

If your home has:

Go to section:

4-wire

4-wire Cable from Home
Power Supply

3-wire

3-wire Cable from Home
Power Supply

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge solid copper wire.

Electrically ground oven.

Failure to follow these instructions can result in death,
fire, or electrical shock.

A

½"

(1.3 cm)

½"

(1.3 cm)

A. Cable from home power supply
B. Black wires

C. Red wires
D. 4-wire flexible conduit from

range

E. Junction box

F. White wires

G. UL listed wire connectors

H. Green (or bare) ground wires

I. UL listed or CSA approved

conduit connector

A. Cable from home power supply
B. Junction box

C. Black wires
D. White wires

E. Green (or bare) ground wire

(from range)

F. 4-wire flexible conduit from

range

G. Red wires

H. UL listed wire connectors

I. UL listed or CSA approved

conduit connector

A
B

C

D

E

F

G

H

I

B

C

D

E

F

H

G

A

I

This manual is related to the following products: