beautypg.com

Bunn -O-Matic Brewer Axiom User Manual

Page 15

background image

Page 15

PROBABLE CAUSE

REMEDY

PROBLEM

TROUBLESHOOTING (cont.)

Check plumbing and shut-off
valves

A) Wait for the brewer to heat
to the proper temperature

B) Disable the BREW LOCK-
OUT function. Refer to program-
ming section for procedure.

Turn on

Service required

Service required

Service required

1. No water

2. Water temperature in the
tank does not meet the ready
temperature.

3. "ENABLE BREW ON/OFF"
switch not on.

4. Brew switch

5. Brew valve

6. Control Board

Brew cycle will not start

Spitting or unusual steaming
from sprayhead or air vent.

1. Lime buildup

2. Temperature probe

3. Control Board

Refer to cleaning section.

Service required

Service required

Inconsistent beverage level

Refer to cleaning section.

Service required

1. Lime buildup

2. Brew valve

Dripping from sprayhead.

Water overfl ows fi lter.

Beverage overfl ows decanter

Service required

BUNN paper fi lters should be
used for proper extraction

Replace sprayhead

The brew cycle should be start-
ed only with an empty decanter
under the funnel.

Adjust the brew volume, cali-
brate sprayhead as required to
achieve the desired volume for
each brew cycle.

1. Brew valve

1. Type of paper fi lter

2. No sprayhead

1. Beverage left in decanter from
previous brew

2. Brew volume adjustment

41154 041708