SPRAY OZ/M: XX.X
LP1-LP2 OZ XX.X
ENTER OZ XX.X
(-) DONE (+)
WaitingTilCycle 4
CYCLE x COMPLETE
CALIBRATE SPRAY
PRESS BREW START
CONTAINER READY?
QUIT YES
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
When the dispensing fi nishes, empty the decanter/server and
place back under brew funnel.
Select YES for calibration. Selecting QUIT will skip to level
probe calibration screen.
Press the "BREW START" button. Will perform the sprayhead
fl ow-rate calibration as well as the level probe calibration.
Brewer must not be bumped during calibration!
Machine will dispense volume between upper probe and
lower probe 4 times. (The total dispense will be about half of
a decanter)
Brewer must not be bumped during calibration!
Enter volume dispensed into container.
Use the (+) to increase the numeric value or (-) to decrease.
Displays sprayhead fl ow-rate and volume of water between
the upper and lower level probes.
Go to CAL
LP1-LP2
CALIBRATE LP1-LP2
NO YES
Allows you to perform calibration again if you want to verify
results.
Go to BREW
COUNTERS
Go to CAL
LP1-LP2