beautypg.com

Indoor coil pistons, Accessory empty coil casing for uncased a-coil – Bryant CC5A User Manual

Page 6

background image

—6—

NOTES:

1. Formulas:

Leaving db = entering db —

Leaving wb = wb corresponding to enthalpy of air leaving coil (h

LWB

)

h

LWB

= h

EWB

where h

EWB

= enthalpy of air entering coil.

2. Direct interpolation is permissible. Do not extrapolate.
3. Fan motor heat has not been deducted.
4. All data points are based on 10°F superheat leaving coil, and use of thermal expansion valve device.
5. All units have sweat suction tube connection and a liquid tube connection. For 1-1/8-in. system suction tube, 3/4- x 1-1/8-in. suction tube connection adapter

is available as accessory.

6. Check-Flo-Rater pistons (sized for matched cooling-only systems). Refer to outdoor unit installation instructions for pistons required for other systems.
7. The CD5A and CC5A coils can be used in any properly designed system using R-22 or Puron® refrigerant.
8. Before using maximum cfm shown in table, check coil static pressure drop to ensure system blower can provide necessary static pressure needed for coil

and duct systems.

Interpolation is permissible.
Correction Factor = 1.09 x (1 – BF) x (db – 80)

BYPASS
FACTOR

ENTERING AIR DRY BULB TEMPERATURE (°F)

79

78

77

76

75

Under 75

81

82

83

84

84

Above 85

Correction Factor

0.10

0.98

1.96

2.94

3.92

4.91

Use formula

shown below

0.20

0.87

1.74

2.62

3.49

4.36

0.30

0.76

1.53

2.29

3.05

3.82

sensible heat cap.

1.09 x CFM

total capacity (Btuh)

4.5 x CFM

INDOOR COIL PISTONS

UNIT

FACTORY-INSTALLED INDOOR PISTON SIZE

CD5AXA018
CC5AXA018

52

CD5AXA024, W024
CC5AXA024, W024

59

CD5AXA030, W030
CC5AXA030, W030

67

CD5AXA036, W036
CC5AXA036, W036

70

CD5AXA042, W042
CC5AXA042, W042

78

CD5AXA048, C048, W048

CC5AXC048, W048

84

CD5AXA060
CC5AXA060

90

CD5AXW060
CC5AXW060

90

ACCESSORY EMPTY COIL CASING FOR UNCASED A-COIL

* Individual casings are sold and shipped in multi-packs as indicated in the 8th and 9th digits.

ACCESSORY PART NO.*

NOMINAL CC5A COIL SIZES

DIMENSIONS (In.) W x H x D

KCAKC1212ECC

A018, A024, A030

14-3/16 x 19 x 21

KCAKC1312ECC

W024, W030, A036

17-1/2 x 20-1/2 x 21

KCAKC1408ECC

W036, A042, C048

21 x 22 x 21

KCAKC1508ECC

W042, W048, A060

24-1/2 x 22 x 21

KCAKC1604ECC

W060

31-1/2 x 22 x 21

This manual is related to the following products: