5— cooling capacities (mbtuh) – Bryant CC5A User Manual
Page 5
—5—
COOLING CAPACITIES (MBtuh)
* Saturated suction leaving evaporator coil
CFM
— Cubic Ft. per Minute
EWB —
Entering Wet Bulb (°F)
LWB —
Leaving Wet Bulb (°F)
TC
—
Total Cooling Capacity 1000 Btuh
See notes on page 6.
UNIT
SIZE
EVAP
AIR
CFM
BF
COIL REFRIGERANT TEMPERATURE* (°F)
35
40
45
50
55
Evaporator Air — Entering Wet Bulb Temperature (°F)
62
67
72
62
67
72
62
67
72
62
67
72
62
67
72
A018
450
22
27
34
18
24
30
14
20
26
11
16
22
9
11
18
0.17
15
15
14
14
13
13
12
12
11
10
10
9
8
8
8
600
26
33
41
22
29
37
18
24
32
14
19
27
12
13
21
0.22
19
18
17
17
16
15
15
14
13
12
12
11
10
10
10
750
30
38
47
25
33
42
20
28
37
17
22
30
14
15
24
0.25
22
21
20
20
19
17
17
17
15
14
14
13
11
12
11
A024
W024
600
28
36
44
24
31
39
19
26
34
15
21
29
13
15
23
0.12
20
20
18
18
17
16
16
15
14
13
13
12
11
11
10
800
34
43
52
29
37
47
23
32
41
19
25
35
16
18
27
0.16
25
24
22
22
21
20
19
19
17
16
16
15
13
14
13
1000
39
49
60
33
43
54
27
36
47
22
29
39
19
20
31
0.18
29
27
25
26
25
23
23
22
20
19
19
17
16
16
15
A030
W030
750
37
46
57
31
41
52
25
34
45
19
27
38
14
16
25
0.13
26
25
24
24
23
22
21
20
19
17
17
16
14
14
13
1000
45
57
70
38
50
63
30
42
55
25
33
46
17
19
30
0.17
33
31
29
29
28
26
26
25
23
21
22
20
17
18
16
1250
52
66
81
44
57
73
35
48
63
29
38
53
20
22
34
0.20
39
36
34
35
23
30
30
29
27
25
25
23
20
21
19
A036
W036
900
42
52
63
35
46
57
28
39
50
22
31
42
19
22
33
0.10
34
32
30
30
29
27
27
26
24
22
22
21
19
19
18
1200
50
62
75
43
55
68
34
46
60
28
37
50
23
26
40
0.13
41
39
35
38
35
32
33
32
29
28
28
25
23
23
22
1500
57
70
84
49
62
76
39
52
67
33
42
57
27
30
45
0.16
48
44
40
44
41
37
39
37
33
33
33
29
27
28
25
A042
W042
1050
45
56
68
38
49
61
31
41
54
25
33
45
20
23
36
0.14
37
54
32
33
31
29
29
28
26
25
24
23
20
21
19
1400
53
66
79
45
58
72
36
49
63
31
39
53
25
26
42
0.17
45
41
37
41
38
34
36
34
31
31
30
27
25
28
23
1750
60
73
87
51
65
80
42
55
70
36
44
60
30
32
47
0.20
52
47
42
47
44
38
42
40
35
36
35
31
30
30
27
A048
W048
1200
48
59
71
41
52
64
33
44
57
30
36
49
22
26
39
0.18
39
36
33
36
34
30
32
30
28
30
27
24
22
23
21
1600
55
68
80
47
60
74
39
51
66
33
41
56
27
30
45
0.22
47
43
38
43
40
35
38
36
32
33
32
29
27
28
25
2000
61
74
88
53
66
81
44
57
72
38
46
62
32
34
50
0.25
54
49
42
50
45
39
44
42
36
38
37
33
32
32
29
C048
1200
44
57
69
36
48
62
30
40
53
25
29
43
20
21
32
0.11
39
36
33
35
33
30
30
29
27
25
25
23
20
21
19
1600
52
65
78
43
56
71
37
46
61
31
35
50
25
25
37
0.15
48
44
38
42
40
35
37
36
32
31
31
28
25
25
24
2000
57
71
85
49
62
78
42
50
68
36
39
55
29
29
41
0.19
55
50
42
49
46
40
42
41
36
36
37
32
29
29
27
A060
1600
57
71
87
48
62
78
38
52
68
31
41
57
26
29
44
0.22
47
44
41
43
40
37
37
36
33
31
31
29
26
26
24
2000
65
80
97
54
70
88
43
59
76
36
46
64
30
33
50
0.25
55
51
46
50
46
42
43
42
38
36
37
33
30
31
28
2400
71
88
105
60
77
95
48
65
83
41
51
70
34
36
55
0.28
62
57
50
56
52
46
48
47
42
41
41
37
34
34
31
W060
1600
63
78
94
54
69
85
43
59
75
35
47
64
29
34
51
0.16
52
48
44
47
44
40
41
40
36
35
35
32
29
29
27
2000
71
88
105
61
78
96
49
66
85
41
53
72
34
39
58
0.19
60
55
50
55
51
46
48
46
42
41
41
37
34
34
32
2400
78
96
114
67
85
104
55
73
93
46
58
79
39
43
64
0.21
68
62
54
62
57
51
54
52
46
46
46
41
39
39
36
BF
—
Bypass Factor
MBH —
1000 Btuh
SHC
— Sensible Heat Capacities (1000 Btuh) shown in
Italic
type. SHC is based on 80°F db temper-
ature of air entering the evaporator coil. Below 80°F db, subtract (corr factor x cfm) from SHC.
Above 80°F db, add (correction factor x cfm) to SHC.