TIMER SETTING - AUTOMATICS ONLY

CAUTION – Disconnect the power source from the brewer prior to the removal

of any panel for the replacement or adjustment of any component.

NOTE: Check that the brewer is connected to water supply, the tank is properly

filled, and a funnel and server are in place, prior to setting or modifying batch sizes.

1. Modifying batch sizes. Turn the ON/OFF Switch to the “ON” position. If the

brewer has a batch selector switch, position it to the size to be changed.

To increase a batch size, Press and hold the START switch until three clicks are

heard. Release the switch (Failure to release the switch within two seconds after

the third click causes the volume setting to be aborted and previous volume setting

will remain in memory) and press it again one or more times. Each time the switch

is pressed, two seconds are added to the brew time period. Allow the brew cycle to

finish in order to verify that the desired volume has been achieved.

To decrease a batch size, Press and release the START switch once for every

two-second interval to be removed from the total brew time period; then immedi-

ately press and hold down the START switch until three clicks are heard. Release

the switch. (Failure to release the switch within two seconds after the third click

causes the volume setting to be aborted and previous volume setting will remain in

memory). Allow the brew cycle to finish in order to verify that the desired volume

has been achieved.

2. Setting batch sizes. Press and hold the START switch until three distinct clicks

are heard (this will take approximately 10 seconds), and then release the switch.

(Failure to release the switch within two seconds after the third click causes the

volume setting to be aborted and previous volume setting will remain in memory).

View the level of the water being dispensed. When the desired level is reached, turn

the ON/OFF switch to “OFF”. The brewer remembers this volume and will continue

to brew batches of this size until the volume setting procedure is repeated. Empty

server(s), flip batch switch to the other position that has yet to be set, and repeat

batch setting procedure until all batch sizes are set.

NOTE: When brewing coffee, batch volumes will decrease due to absorption by

the coffee grounds.