Accessories, Installation ć step by step, Caution – Bosch WTMC1301CN User Manual
Page 8
8
Exhaust vent hood
The exhaust duct must end with an
approved exhaust vent hood with
swing out damper(s). DO NOT use an
exhaust vent hood with magnetic
latches.
To avoid exhaust restriction, the outlet
must be a minimum of 12 inches (30
cm) above ground level or any other
obstructing surface.
Required parts
The parts required for the exhaust air
system (elbows, lines, exhaust air
outlets) are not included in standard
delivery of the dryer.
Accessories
The parts required for the exhaust air
system can be obtained from customer
service or your local dealer. Please
follow the installation instructions
supplied by the appropriate
manufacturer!
Side exhaust kit
part no. WTZ 1265
Note:
The maximum permitted number of 90°
elbows (including this side exhaust kit)
is four!
i
Special tool for cutting the hole in
prepared side panel is required.
Contact local dealer!
Bottom exhaust kit
part no. WTZ 1270
Note:
The maximum permitted number of 90°
elbows (including this side exhaust kit)
is four!
Dryer rack
part no. WTZ1290
Use the dryer rack to dry washable
woolen textiles (e.g. sweaters) and
shoes.
Left hinge kit
part no. WTZ1260
The door catch can be reversed if
necessary. The door is hinged on the
right at the factory.
Pedestal Mounting Kit
part no. WTZ 1295
If mounting the dryer on the pedestal
follow the instructions supplied with the
pedestal.
Installation ć
step by step
1. Unpack the dryer.
2. Remove all objects from the drum.
3. Check the dryer for visible
damage.
4. Position the dryer near the
installation location.
5. If required, change the door hinges
to the left (see page 5).
6. If required, have customer service
install the exhaust air outlet on the
dryer (see page 7).
7. Have the power supply cord fitted
by an authorized technician (see
page 5).
8. Install exhaust duct if necessary.
Follow the installation instructions
supplied by the appropriate
manufacturer!
i
If space is very restricted, it is
recommended to fit the initial parts
of the exhaust duct to the dryer
before the dryer is moved to its
final installation location.
9. Move the dryer to its final location
and align.
CAUTION
Do not slide dryer across the
floor if heightĆadjustable feet
have been extended. Feet and/or
dryer base may be damaged if
dryer is slid across floor with
heightĆadjustable feet extended.
10. Position and then level the dryer
.
The dryer should be level with all
four feet firmly on the ground. The
dryer must not wobble. If the dryer
is not level or if it does wobble, the
feet must be adjusted. Adjust the
heightĆadjustable feet until the
dryer does not rock and is level,
both frontĆtoĆback and
sideĆtoĆside.
11. Connect the exhaust duct to the
exhaust air outlet on the dryer.
12. Insert plug into the wall receptacle.