beautypg.com

Bunn CWTF-TS-MV User Manual

Page 9

background image

Page 9

TROUBLESHOOTING (cont.)

PROBLEM

Brew cycle will not start (cont.)

Water is not hot

PROBABLE CAUSE

REMEDY

5. Timer

6. Solenoid Valve

7. Water strainer/flow control
(.222 GPM)

1. Tank Heater Switch

2. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat. Use only
replacement part #29329.1000

3. Control Thermostat

4. Tank Heater(s)

5. Fuse Holder and Fuse Assembly

6. Thermal Fuse

Refer to

Service

- Timer for testing

procedures. See page 26 or 27

Refer to

Service

- Solenoid Valve

for testing procedures. See page
19

(A) Direction of flow arrow must
be pointing towards brewer.

(B) Remove the strainer/flow con-
trol and check for obstructions.
Clear or replace.

Refer to

Service

- Tank Heater

Switch for testing procedures. See
page 23

Refer to

Service

- Limit Thermo-

stat for testing procedures. See
page 17

Refer to

Service

- Control Ther-

mostat for testing procedures. See
page 15

Refer to

Service

- Tank Heater(s)

for testing procedures. See page
21

Refer to

Service

-Fuse Holder and

Fuse Assembly for testing proce-
dures. See page 16

Refer to

Service

- Thermal Fuse

for testing procedures. See page
25

28182 090100