Water leakage test – Olympus PT-EP10 User Manual
Page 16
EN 15
EN
Water leakage test
The final test after loading the camera is explained below. Always perform this test. It can be performed
easily in a water tank or a bathtub. The required time is about five minutes. Confirm the operation of the
different buttons.
• At first, immerse the Case for only three seconds and check that no water drop etc. to inside of the
Case.
• Next, immerse the Case for 30 seconds and check that no water drop etc. to inside of the Case.
• Then, immerse the Case for three minutes, operate all buttons and levers, and check the following:
- check that no water has accumulated inside of the Case.
- check that the Case is not fogged.
- check that no water has entered inside of the Case.
• If inside of the Case is fogged or there is a water drop, do the maintenance of the O-ring and perform
the water leakage test again.
PT-EP10_EN.Book Page 15 Thursday, September 20, 2012 5:44 PM