6

WARNINGS AND CAUTIONS

• Always remember to turn off the Aries

scope when it is not in use. If you do not

plan on using your aries scope for a period

of more than 10 days, you should remove

the batteries.

• Keep lens cap/daylight filter on when

not in use.

• Avoid contact with dust, steam, and gas.
• The Aries scope are not harmful to the user

or the environment.

• Do not disassemble except to clean the

front lens and the eyepiece:

it will void

your warranty.

• Evaluate the scopes function by looking

through it in a lit environment with the

daylight filter lens cap on. Never use in

daylight without the daylight filter lens cap

on. Do not surpass ten minutes of testing.

Never point the Aries scope at a bright

light source. If the scope shuts off auto-

matically after directing it at a bright light

source, turn the unit off and wait 1 - 2 min-

utes before turning the unit back on.

• Adverse atmospheric conditions such as

fog, smog, or haze and a lack of ambient

light (moon or starlight) may diminish the

effective viewing distance. All technical

data for this unit was compiled in a control-

led environment.

TROUBLESHOOTING

Q: Flashes, flickers, or clicking occur while

operating
S: If it occurs within the first five minutes of

inserting new batteries, it is normal and the

device will resume normal operation soon

thereafter. If it occurs for more than 10 min-

utes, contact your dealer or other authorized

service representative for service instruc-

tions.
Q: Dark spots on screen.
S: This may be dust on the lens, please

clean according to instrutions. They may

also be Cosmetic blemishes in the intensifier

tube which are a by-product of the manufac-

turing process. This is normal and will not

affect the life or performance of the unit.

Q: Image not clear.
S: Adjust focus ring. If problem persists,

increase viewing distance
Q: Fixed-pattern noise in a honeycomb

shape.
S: Usually a cosmetic blemish character-

ized by a faint honeycomb-type pattern. This

usually occurs when viewing very bright

lights. Adjust the potentiometer, to reduce

brightness.
Q: A pattern of dark thin lines which look like

chicken wire.
S: Turn on illuminator, if purchased. If illu-

minator doesn’t brighten image, replace

batteries. If problem persists, contact ATN

for service instructions.

You may need to clean the eyepiece of the

riflescope from time to time in order to guar-

antee top performance. When you receive

your riflescope you should check for dust on

the eyepiece of the unit.
First you will need to remove the eyepiece.

To do that you will need to initially loosen the

2 set screws that can be found on the base.

Then unscrew the eyepiece counter-clock-

wise to remove it.

NOTE: You do not have to remove the set

screws completely, they are very small and

easy to misplace.
CAUTION: Use only Photographic lens clean-

ing tissue on these surfaces. Be careful not

to scratch or smudge any of these surfaces.

When using compressed air to blow dust

away, make sure to avoid inverting the can

while spraying. This can cause frozen propel-

lant to exit the can, which can cause serious

problems with the glass and phosphor screen.

CLEANING THE EYEPIECE