Action

System Response

Turn ignition on

No response

Press and release the valet switch 3 times

1 Chirp - LED 1 flash

Within 3 seconds, turn ignition Off, On, Off, On

Short chirp, then 2 long chirps

This Action Accesses Feature Bank 3 Remote Start Selectable Features

First

Press the valet switch one time

1 chirp = defrost output pulsed

Press transmitter Lock button to change

2 chirps = defrost output 10 Mins

o r

Second

Press and release the valet switch

2 chirps = RF start chirp on

Press transmitter Lock button to change

1 chirp = RF start chirp off

o r

Third

Press and release the valet switch

2 chirps = run time set for 10 mins

Press transmitter Lock button to change

3 chirps = run time set fro 15 mins

Press transmitter Lock button to change

4 chirps = run time set for 20 mins

Press transmitter Lock button to change

1 chirp = run time set for 5 mins

o r

Fourth

Press and release the valet switch

1 chirp = parking lights on steady w/RS active

Press transmitter Lock button to change

2 chirps = parking lights flashing w/RS active

o r

Fifth

Press and release the valet switch

2 chirps = tachometer input checking

Press transmitter Lock button to change

1 chirp = voltage sense input checking

o r

Sixth

Press and release the valet switch

1 chirp = greater than 0.5 V check before start

Press transmitter Lock button to change

2 chirps = less than 0.5 V check before start

o r

Seventh

Press and release the valet switch

2 chirps = ign 2 on during crank

Press transmitter Lock button to change

3 chirps = ign 2 same as accessory

Press transmitter Lock button to change

1 chirp = ign 2 off during crank

o r

Eighth

Press and release the valet switch

2 chirps = ign 3 on during crank

Press transmitter Lock button to change

3 chirps = ign 3 same as accessory

Press transmitter Lock button to change

4 chirps = Ign 3 same as starter

Press transmitter Lock button to change

1 chirp = ign 3 off during crank

o r

Ninth

Press and release the valet switch

1 chirp = diagnostics off

Press transmitter Lock button to change

2 chirps = diagnostics on

o r

Tenth

Press and release the valet switch

2 chirps = crank time 1.0 sec

Press transmitter Lock button to change

3 chirps = crank time 1.5 sec

Press transmitter Lock button to change

4 chirps = crank time 2.0 sec

Press transmitter Lock button to change

1 chirp = crank time 0.8 sec

o r

Eleventh

Press and release the valet switch

1 chirp = unit set for gasoline engine

Press transmitter Lock button to change

2 chirps = unit set for diesel engine 10 sec delay

Press transmitter Lock button to change

3 chirps = unit set for diesel engine 15 sec delay

Press transmitter Lock button to change

4 chirps = unit set for diesel engine 20 sec delay

o r

Twelfth

Press and release the valet switch

1 chirp = transponder output while R/S active

Press transmitter Lock button to change

2 chirps = transponder output during start only

Press transmitter Lock button to change

3 chirps = transponder output until ignition turned off

o r

Thirteenth

Press and release the valet switch

Non Functional On This Unit

o r

Fourteenth

Press and release the valet switch

1 chirp = crank averaging w/voltage input checking

Press transmitter Lock button to change

2 chirps = preset crank time w/voltage input check

Fifteenth

Non Functional On This Unit

o r

Sixteenth

Press and release the valet switch

1 chirp = turbo timer off

Press transmitter Lock button to change

2 chirps = turbo timer 3 mins

Press transmitter Lock button to change

3 chirps = turbo timer 5 mins

Press transmitter Lock button to change

4 chirps = turbo timer 10 mins

o r

Seventeenth

Press and release the valet switch

1 chirp = aux o/p Black/Blue single pulse

Press transmitter Lock button to change

2 chirps = aux o/p Black/Blue as alarm feature #1

Press and release the valet switch

or

turn the ignition off to:

Exit Programming Mode

Note : Once you enter the feature programming mode, do not allow more than 15 seconds to pass between steps or the

programming will be terminated.