It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a mini-
mum gap of 3 mm between the switch
contacts and of a type suitable for the
required load in compliance with the
current regulations.
The switch must not break the yellow
and green earth cable at any point.
After installation and connecting,
the cable must be placed so that
it cannot at any point reach a
temperature of more than 50°C
above the ambient temperature.
Before the oven is connected,
check that the main fuse and the
domestic installation can support
the load; and that the power sup-
ply is properly earthed.
The manufacturer declines any respon-
sibility should these safety measures
not be carried out.
440
547
567
594
333
455
21
448-452
min.
550
min.
560
15
36 www.aeg.com