Maintenance and cleaning – AEG X67453MD0 User Manual
Page 11

MAINTENANCE AND CLEANING
11
MAINTENANCE AND CLEANING
Alarm signal reset
• Turn the Lights and the Suction Motor off.
• Touch button
F. The operation is confirmed when the Led
goes out.
Before carrying out any maintenance or cleaning isolate
the cooker hood from the mains supply.
Charcoal Filters
In the recirculation mode the charcoal filters absorb smells and
unwanted odours.
This cannot be washed or regenerated, and must be changed
when the led on button
F starts to flash, or at least once every
4 months.
Enabling/Disabling the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm
must be activated on installation or at a later date.
• Turn the Lights and the Suction Motor off.
• Press button
F and hold it for 4 seconds until the LED
lights up in confirmation:
•
Led lights up for 4 seconds – Activated Charcoal
Filter saturation alarm
ACTIVATED.
•
Led lights up for 2 seconds – Activated Charcoal
Filter saturation alarm
DEACTIVATED.
To Remove the Charcoal Filters
• Remove the metal grease filters.
• Remove the saturated activated carbon filter by releasing the
fixing hooks.
• Fit the new filter by hooking it into its seating.
• Refit the metal grease filters.
This appliance can be a possible fire hazard if the grease
and charcoal filters are not cleaned and replaced as
recommended.